WOLF COOKTOP LOW-PROFILE HOODS
IN-LINE AND REMOTE BLOWERS
IMPORTANT NOTE:
For mounting and
installation of an in-line or remote blower,
refer to the specific installation instructions
provided with each blower.
Locate the in-line or remote blower so that the
length of the duct run and number of elbows
and transitions are kept to a minimum. Wolf
recommends the maximum linear duct run
be no greater than 50' (15 m).
Be sure that there is enough space for any
transitions that may be needed between the
blower and the connecting ductwork. For best
performance, locate transitions nearest the
blower.
Refer to the illustrations below for overall
dimensions of Wolf in-line blowers.
To reduce the risk of fire and electric
shock, install this ventilation hood only
with Wolf in-line blowers 808331 or
808332, or Wolf remote blowers 801640,
801641, 801642 or 804701.
The blower must be UL listed for Canadian
and U.S. use, and evaluated for use with
solid state speed control, rated 120 V,
60 Hz, 6.0 A max.