4
|
Wolf Customer Care 800.222.7820
Ducting
WARNING
Use only rigid metal ducting.
Consult a qualied HVAC professional for specic installa-
tion and ducting applications.
The hood accommodates a 6"
(152) round duct.
A straight, short duct run is most effective and will ensure
proper performance.
Use sheet metal screws and aluminum tape or high temper-
ature duct tape to seal joints between ducting sections.
The hood includes a backdraft damper. Local codes may
require the use of an additional backdraft and/or make-up
air damper. Contact your local HVAC professional for spe-
cic requirements.
A make-up air damper is available through an authorized
Wolf dealer.
CAUTION
To reduce the risk of re and to properly exhaust air,
duct air outside. Do not vent exhaust air into spaces
within walls, ceilings, attics, crawl spaces, or garages.
RECIRCULATION APPLICATION
The hood can be installed in a recirculation application.
Refer to the illustration below.
A vent cover is provided with the hood. Ductwork is not
provided.
Recirculating lters, available through an authorized Wolf
dealer, are required.
SITE PREPARATION
HORIZONTAL
DISCHARGE
DISCHARGE
ABOVE CABINET
Recirculation application