Water Valve Replacement
Water Valve Replacement: 500, 550, 600, 611, 632, 650, 690, 700.
Recommend appliance professional for BI-30, BI-36, BI-42, BI-48, PRO48
Replacement of your water valve can be done without the removal of the unit. Shutdown
power and water source to the unit. This is generally located in a common area, possibly
under the sink or in the basement under the unit itself.
For all 500 and 600 series units, the valves are located on the bottom left. All early 700
series units have the valves on the right. You will need to remove the two to four Philip
screws under the toe-kick panel.
Use a wrench to disconnect copper or braided line from the valve. The valve will be secured
by a Philip screw then will pull out a few inches. This will allow room to disconnect electrical
connections and then the plastic coupling on the back side of valve.
The valve can then be removed and replaced with new valve. Put new valve back in reverse
order and tighten (but don’t over tighten). Turn water supply on and check for leaks.