MODEL 801642
Page 3
OUTSIDE - ROOF VIEWOUTSIDE - WALL VIEW
10 Cover
Screws
10 Cover
Screws
Bird Screen
Flashing
Sheet
Drill 6
Mounting
Holes
Damper
22"
29½"
14
11
/
16"
11
13
/
16
"
Wall Stud
Wall Stud
11" dia.
hole
17"
1¼" dia. hole
3
"
REMOVE
SIDING
Pilot Hole
(centered between studs)
PREPARE THE WALL
WIRE THE VENTILATOR
From inside the wall:
1 Drill a PILOT HOLE through the wall, centered between
WALL STUDS.
From outside - on the wall:
2 Measure and mark the 22" x 29½" rectangle. Cut and remove
only the siding inside this rectangle.
3 Measure and mark the 11" DIAMETER HOLE and the 1¼"
DIAMETER HOLE. Cut these holes all the way through the
wall.
BLACK TO BLACK
WHITE
TO
BLUE
120
VAC
LINE
IN
GROUND
TO
GROUNDING
SCREW
INSTALL THE VENTILATOR
4 Remove 10
COVER SCREWS
and lift off
ventilator cover.
5 Feed the electric
power cable
through the 1¼"
DIAMETER HOLE
and connect cable
to ventilator with a
proper connector
for the type of
cable being used.
6 Connect BLACK
TO BLACK,
WHITE TO BLUE,
and GROUND
TO GROUNDING
SCREW.
7 Place ventilator on wall so that ventilator's discharge collar
fits into 11" diameter hole.
8 Use the 6 screws (provided) to attach the ventilator to the
wall. DRILL 6 MOUNTING HOLES inside the ventilator, as
necessary.
9 Seal the screw heads and edges of the flashing sheet with
a good grade of roofing cement.
10 Check for free movement of the spring-loaded DAMPER
and re-install ventilator cover. Turn on power and check
operation.
WALL MOUNT
INSTALLATION
For use with Models CTWH30, CTWH36, IH4227, DD30R, DD36R, DD45R, W30-662418, W30-662718,
I36-663418, L34-582212.