I N S TA L L AT I O N I N S T R U C T I O N S
O V E R H E A D C A B I N E T D I M E N S I O N S
C)
Minimum spacing between overhead side
cabinets must be greater than or equal to
the nominal width of the module(s).
D)
Minimum 457 mm vertical distance from
the countertop to the bottom of side
cabinets within minimum side clearance.
E)
Minimum vertical distance between the
countertop and combustible materials
above the cooktop module must be
762 mm. Where this is not practicable, the
underside of any combustible material less
than 600 mm above the burner shall be
protected by non-combustible mill board at
least 6 mm thick which is covered with
sheet metal not less than 0.4 mm thick, or
shall be protected by an equivalent
material, extending at least 225 mm beyond
the sides of the cooktop.
Range hoods and exhaust fans shall be
installed in accordance with the manufac-
turer’s instructions. However, in no case
shall the clearance between the top of the
burner and the underside of the range hood
be less than 750 mm, or an overhead
exhaust fan, 750 mm.
F)
Minimum 64 mm from rear wall.
G)
Maximum 330 mm depth of overhead and
side cabinets directly above and within side
clearance.
S I T E P R EPA RATI O N
Check the location where the cooktop will
be installed. The location should be away
from strong draft areas, such as windows,
doors and strong heating vents or fans. Do
not obstruct flow of combustion and
ventilation air.
IMPORTANT NOTE:
Installation of the Wolf
gas multi-function cooktop must meet the
following location requirements. All dimen-
sions listed are minimum requirements for
safe operation. Refer to the illustration on this
page.
Failure to locate the cooktop module
without the proper clearances will result
in a fire hazard.
Minimum installation clearances
L O C A T I O N I N C O U N T E R T O P
A)
Minimum flat countertop surface. Must be
equal to or greater than the width of the
module(s).
B)
Minimum 200 mm wide clearance from the
periphery of the nearest burner to any
combustible surface up to 457 mm above
the countertop (noted by shaded area).
If the distance measured from the periphery
of the burner to any vertical combustible
surface, is less than 200 mm, the surface
shall be protected in accordance with
clause 5.12.1.1 and 5.12.1.2 of AS 5601.
WOK installation_Mono 1.0:Intl Multi-F CT Install 31/3/10 1:26 PM Page 5