Wolf ICBIM15 Especificações Página 7

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 6
7
I N S TA L L AT I O N I N S T R U C T I O N S
I N S TA L L AT I O N OP T IO N S
MU LTI PL E CO OK T OP IN S TALL ATI ON
If the multi-function cooktop is to be used with
any combination of additional cooktop units or
modules with a filler strip, the cut-out width is
calculated by adding the corresponding units'
cut-out dimensions plus 32 mm for each addi-
tional unit. Refer to the illustration below.
IMPORTANT NOTE:
When multiple cooktops
and/or modules are installed side by side, each
unit must have its own separate recommended
electrical circuit. They must also have their own
seperate regulator and gas line.
When two or more modules are installed
together, an integrated module filler strip
(IFILLER/S) is recommended. Contact your Wolf
dealer for information on these accessory
components.
IMPORTANT NOTE:
Review specific installation
instructions for product to product capabilities.
Gas c onnection:
The cooktop is adjusted to
operate on the gas type
specified on the gas type
label located on the
bottom of the unit. If in
doubt as to the type of
gas available contact the
network operator or gas
supplier for confirmation
of gas type.
The cooktop must be connected to the gas
supply with upstream connection of an isolation
valve in accordance with the respectively valid
regulations. We recommend that the isolation
valve be fitted prior to the cooktop to enable
isolation of the cooktop from the gas supply.
The valve must be easily accessible at all times.
This appliance may be
connected with a hose
assembly, class B or class D in
accordance to AS/NZS 1869.
If connected with a hose
assembly ensure that the gas
supply connection point is
accessible with the appliance
installed.
The position of the inlet connec-
tion is measured from bottom
RH rear of unit, 40 mm centre
line from rear and 55 mm
centre line from RH side.
WOK installation manual:Intl Multi-F CT Install 6/6/11 1:45 PM Page 7