Wolf CT15I/S Especificações Página 7

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 6
7
Dimensions in parentheses are in
millimeters unless otherwise specified.
2"*min (51)
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
18"
(457)
19
1
/4" (489)
COOKTOP CUT-OUT
DEPTH
2
1
/2"min
(64)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
13" max
(330)
30" (762)
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
24"min
(610)
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18" (457) above countertop. **Minimum clearance
from rear edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.
3
3
/4"min
(95)
30-INCH OVEN OPENING
4
1
/2"
(
114
)
10"
(254)
3
1
/2" (89)
E
28
3
/8" (721) COOKTOP
CUT-OUT WIDTH
28
3
/8" (721)
COOKTOP CUT-OUT WIDTH
FRONT OF COUNTERTOP
2
1
/2"min
(64)
19
1
/4" (489)
COOKTOP
CUT-OUT DEPTH
33" (838)
RECOMMENDED
C
ABINET WIDTH
30"min (762)
2"**
(51)
Overall Dimensions
Countertop Cut-Out
21"
(533)
OVERALL
DEPTH
30" (762)
OVERALL WIDTH
TERMINAL BOX
3
1
/2" (89)
4
1
/2" (114)
MODEL CT30I/S
The illustrations below provide installation
specifications for Model CT30I/S.
For ease of installation, 33" (838) cabinets are
r
ecommended for installation of Model
CT30I/S.
A Wolf 30" (762) or 36" (914) built-in single
oven may be installed below Model CT30I/S.
For this installation, unless you are using
cabinets deeper than 24" (610), it is recom-
mended that the electrical supply be placed in
the base cabinet to the right of the oven.
Refer to installation instructions provided with
the built-in oven for additional specifications.
If Model CT30I/S is installed above cabinets,
t
he electrical placement is not critical. A
grounded electrical box should be located
within 4' (1.2 m) of the right rear of the
c
ooktop.
MODEL CT30I/S
Overall Width 30" (762)
Overall Height 3
1
/2" (89)
Overall Depth 21" (533)
Minimum Cabinet Depth 22
3
/4" (578)
Minimum Height Clearance*4
1
/2" (114)
Cut-Out W
idth 28
3
/8" (721)
Cut-Out Depth 19
1
/4" (489)
INSTALLATION SPECIFICATIONS MODEL CT30I/S
Dimensions in parentheses are in
millimeters unless otherwise specified.
*
Minimum
6
"
(
1
5
2
)
clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 5.
Dimensions may var
y to
±
1
/8" (3).
INSTALLATION INSTRUCTIONS
Vista de página 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 15 16

Comentários a estes Manuais

Sem comentários