Wolf CT30G/P Especificações Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 100
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
21
Dimensions in parentheses are in
millimeters unless otherwise specified.
WOLF GAS COOKTOPS
9"*min (229)
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
18"
(457)
19
1
/4" (489)
COOKTOP CUT-OUT
DEPTH
2
1
/2"min
(64)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
13" max
(330)
30" (762)
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
2
1
/2"**
(64)
24"min
(610)
*Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18" (457) above countertop.
**Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.
4" (102)
10"
(254)
3
1
/2" (89)
E
3
3
/4"min
(95)
G
30-INCH OVEN OPENING
29" (737) COOKTOP
CUT-OUT WIDTH
29" (737)
COOKTOP CUT-OUT WIDTH
FRONT OF COUNTERTOP
2
1
/2"min
(64)
19
1
/4" (489)
COOKTOP
CUT-OUT DEPTH
33" (838)
RECOMMENDED
CABINET WIDTH
30"min (762)
21"
(533)
OVERALL
DEPTH
30" (762)
OVERALL WIDTH
4" (102)
Countertop Cut-Out Dimensions
OVERALL DIMENSIONS
30" (762) Gas Cooktop
INSTALLATION SPECIFICATIONS
30" (762) Gas Cooktop
SPECIFICATIONS
30" (762) Gas Cooktop
Overall Width 30" (762)
Overall Height 4" (102)
Overall Depth 21" (533)
Burner Rating (1) 15,000 Btu/hr
(4.4 kW) with
800 Btu/hr (.2 kW)
delivered at simmer
(1) 12,000 Btu/hr
(3.5 kW) with
800 Btu/hr (.2 kW)
delivered at simmer
(2) 9,200 Btu/hr
(2.7 kW) with
300 Btu/hr (.1 kW)
delivered at simmer
Cabinet Width 33" (838) rec
Cabinet Depth 22
3
/4" (578) min
Height Clearance 4" (102) min
Cut-Out Width 29" (737)
Cut-Out Depth 19
1
/4" (489)
Electrical Supply 120 V AC, 60 Hz
15 amp dedicated circuit
Power Cord 6' (1.8 m) 3-prong
Gas Rating 45,400 Btu/hr
(13.3 kW)
Shipping Weight 50 lbs (23 kg)
Unit dimensions may vary to ±
1
/
8
" (3).
INSTALLATION OPTIONS
A Wolf 30" (762) single oven may be installed
below the Wolf 30" (762) gas cooktop. For
this installation, unless you are using
cabinets deeper than 24" (610), it is recom-
mended that the electrical and gas supply
be placed in the base cabinet to the right of
the oven. Refer to page 6 for additional
specifications.
Unit dimensions may vary to ±
1
/
8
" (3).
MODEL OPTIONS
30" (762) Gas Cooktop
Classic / Natural Gas
CT30G/S
Platinum / Natural Gas
CT30G/P
Classic / LP Gas CT30G/S-LP
Platinum / LP Gas CT30G/P-LP