Ventilation Recommendations 112
V
entilation recommendations on the following pages
provide Wolf product CFM and blower options for each
ventilation hood and downdraft.
Refer to the illustrations below for dimensions of Wolf in-
line and remote blowers. Installation instructions shipped
with each Wolf ventilation product provide detailed specifi-
cations. These instructions can also be found on our
website, wolfappliance.com/specs.
Blower Assemblies
F
or Wolf ventilation hoods and downdrafts that do not
include a blower assembly, an internal, in-line or remote
blower assembly must be selected to accommodate the
cooking appliance, CFM requirements and homeowner
preferences. Internal, in-line and remote blowers are
available through your authorized Wolf dealer. For local
dealer information, visit the find a showroom section of
our website, wolfappliance.com.
24
1
/2
"
(622)
15
1
/2
"
(394)
28
1
/4
"
(718)
20
3
/4
"
(527)
24
3
/4
"
(629)
14"
(356)
4
3
/4
"
(121)
10" (254)
DIAMETER
14
3
/4
"
(375)
29
1
/2
"
(749)
29
1
/2
"
(749)
18" (457)
22"
(559)
10
1
/8
"
(257)
7
1
/4
"
(184)
10"
(254)
10" (254)
DIAMETER
1200 CFM
14
3
/4
"
(375)
29
1
/2
"
(749)
29
1
/2
"
(749)
21" (533)
25"
(635)
10
3
/8
"
(264)
7
1
/4
"
(184)
10"
(254)
10" (254)
DIAMETER
1500 CFM
11
3
/4"
(
298)
21
1
/2"
(546)
24
3
/8"
(619)
18
1
/2"
(470)
12
1
/4"
(311)
4
1
/2"
(114)
In-Line Blowers
600 CFM
18"
(457)
22"
(559)
24
7
/8
"
(632)
12"
(305)
18"
(457)
8"
(203)
1100 CFM
Remote Blowers
600 CFM AND 900 CFM
RANGES / RANGETOPS
VENTILATION
COOKTOPS OVENS / WARMING DRAWERS
OUTDOOR GRILLS