Ventilation Recommendations 113
wolfappliance.com/specs
Wolf Product CFM
*Downdraft systems are not recommended for use with these models.
CFM are based the cooking appliance output. Wolf suggests 1 CFM per 100 Btu
(.03 kW). Additional CFM may be required for long duct runs or
ranges and rangetops with a charbroiler or griddle.
COOKTOP HOODS DOWNDRAFTS PRO HOODS
MODEL CFM CFM CFM
COOKTOPS AND MODULES
CT15I CT15E CT15G IG15* IS15* IF15* IM15 215 150 215
C
T30I CT30IU* CT30E CT30EU* CT30G 450 350 500
CT36I CT36IU* CT36E CT36EU* CT36G 600 500 500
DUAL FUEL RANGES
D
F304 500
DF366 DF364C DF364G 900
D
F486C DF486G DF484CG DF484DG DF484F 1100
DF606DG DF606F DF606CG DF604CF DF604GF 1500
SEALED BURNER RANGETOPS
SRT304 500 500
SRT366 500 900
SRT364C SRT364G 900
SRT486C SRT486G SRT484CG SRT484DG SRT484F 900
GAS RANGES
R304 500
R366 R364C R364G 900
R488 R486C R486G R484CG R484DG R484F 1100
R606DG R606F R606CG 1500
RANGES / RANGETOPS
OVENS / WARMING DRAWERS
OUTDOOR GRILLS
VENTILATION
COOKTOPS
Comentários a estes Manuais