14
G A S S U P P LY R E Q U I R E M E N T S
G A S S U P P LY C O N N E C T I O N
IMPORTANT NOTE:
The gas range must be
connected to a regulated gas supply.
Provide a gas supply line of
3
/4" rigid pipe to
the range location. A smaller size pipe on long
r
uns may result in insufficient gas supply. Pipe
joint compounds, suitable for use with LP gas
should be used. For LP gas, piping or tubing
size can be
1
/2" minimum. LP gas suppliers
usually determine the size and materials used
on the system. If local codes permit, a certified,
3' (.9 m) long,
1
/2" or
3
/4" ID flexible metal
appliance connector is recommended for
connecting this range to the gas supply line.
The pipe coming out the back of the range
has
1
/2" female threads.
IMPORTANT NOTE:
The supply line must
be equipped with an approved external gas
shut-off valve located near the range in an
accessible location. Do not block access to the
shut-off valve. Refer to the illustration below.
The Wolf gas range functions up to 6,000'
(1828 m) in altitude without any adjustment. If
installation is above 6,000' (1828 m), contact
your Wolf dealer.
EXPLOSION HAZARD—
Use a certified gas supply line and install
a gas shut-off valve.
Securely tighten all gas connections.
The maximum gas supply pressure to the
regulator should never exceed 14" (34.9
mb) WC (water column); .5 psi (3.5 kPa).
F
ailure to do so can result in explosion,
fire or death.
W O L F G A S R A N G E S
Gas Supply
LineTo Appliance
SHUT-OFF VALVE
Open Position
Shut-off valve
I
M P O RTA N T
N O T E
This installation
must conform with
local codes and
ordinances. In the
absence of local
codes, installations
must conform with
the American
National Standard,
National Fuel Gas
Code.
T Y P E S O F G A S
There are two types of gas, natural and liquid
propane (LP). Conversions are required in
order for appliances designed for one gas to be
operated with the other gas. Such conversions
must be performed by a Wolf authorized service
center. Make sure your gas range is correctly
adjusted for the type of gas being used.
The product rating plate has information on
the type of gas that should be used. If this
information does not agree with the type of
gas available, check with the local gas supplier.
The rating plate is located under the drip pan
that supports the cooking grates, on the left
inside wall of the range. Refer to the illustra-
tion on page 3. The rating plate for Model
R482CF is located on the right inside wall.