NOTE Regulators come preset, but should be
checked anytime one is installed. Before adjusting
regulator, check incoming gas line pressure. Incoming
pressure must be 6-14" W.C. for natural gas and
11-14" W.C. for propane gas. If incoming pressure is
not correct, have the gas source checked and
adjusted as necessary. Make sure the regulator is
mounted in the horizontal position with the arrow
pointing in the direction of gas flow. See unit data
plate, riveted inside the kick panel, for manifold
pressure setting information. Clean vent cap before
adjusting.
)LJ
1. Connect manometer to either of the pressure
taps provided on the range gas piping between
the burner control valve sets.
)LJ
2. Check manometer reading. The reading should
be 5" W.C. for natural gas and 10" W.C. for
propane gas. Tolerance is ±0.3" W.C.
3. If manifold pressure is not correct, adjust the
regulator. Remove the regulator closing nut.
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - SERVICE PROCEDURES AND
ADJUSTMENTS