4. Insert a flat edge screwdriver through the top of
the regulator. While watching the manometer,
turn the adjusting screw clockwise to increase
pressure and counterclockwise to decrease
pressure.
5. Install the regulator closing nut.
6. Apply thread sealant to pressure tap plug and
reinstall. Thread sealant must be insoluble in
propane and natural gas.
%URNERNO==LEC+EC.
The burner nozzle is mounted between the oven gas
supply tubing/mounting bracket and the u-burner
assembly. If burner operation seems poor and other
systems have been checked, access the burner for
the range section being serviced and remove the
burner nozzle.
Check for blockage or damage.
Verify gas orifice hood is correct for the altitude.
See Parts Catalog for Orifice Hood Chart.
O9EN%URNERNO==LE6+O:N
6TANDARDO9ENT+ER0O6TAT
%<3A66)LA0EAD-U6T0ENT
NOTE By-pass flame can be viewed through the kick
panel for adjustment.
1. Turn the thermostat knob to 350°F.
2. Wait 10 minutes for oven to heat up.
3. Turn thermostat knob to lowest setting.DONOT
TURNO)).
4. Remove thermostat knob.
5. With a screwdriver, turn by-pass flame
adjustment screw counterclockwise to increase
by-pass flame or clockwise to decrease flame
until the entire burner has approximately a 1/8"
stable flame on each port.
NOTE Some flickering of the flame is acceptable.
This is most likely to occur in the bend of the burner.
)LJ
6. Replace thermostat knob.
A. Turn knob to 350°F and verify increase in
flame height on burner ports.
7. Turn knob back to lowest setting. Verify decrease
in by-pass flame height on burner ports and that
burner remains lit.
6TANDARDO9ENT+ER0O6TAT
TE03ERATUREAD-U6T0ENT
A thermocouple type temperature probe should be
placed in center of oven to verify temperatures
throughout adjustment.
NOTE Calibration on this thermostat version is made
using the knob for temperature adjustments and not
the inner screw as on previous versions.