GRIDDLET+ER0O6TATCO0%O
9AL9EAD-U6T0ENT
OSHUDWLRQ
The thermostat-combo valve is self-regulating and the
thermostat is internally connected to the valve. When
thermostat dial is set to 350°F and the griddle is below
setpoint, the valve opens to allow gas flow and burner
lights. As the griddle temperature rises, the pressure
from the sensor bulb secured to the bottom of the
griddle plate increases. Fluid in the capillary tube
expands with the temperature increase and presses
against a diaphragm in the thermostat. When the
griddle temperature reaches setpoint, the internal
valve closes to stop gas flow to burner.
When the griddle temperature decreases below
setpoint, the pressure is reduced in the capillary which
reduces the force on the diaphragm allowing the valve
to open again.
AGMXVWPHQW
A thermocouple type surface temperature probe
should be placed in center of griddle to verify
temperatures throughout adjustment.
1. Turn dial to 350°F. Allow griddle to cycle 3
complete times.
2. Take a temperature reading. If temperature is
more than 20°off dial setting, calibrate as follows.
3. Pull off thermostat knob. Do not rotate knob
during removal.
4. Hold outer shaft in place. Do not allow to move.
5. Turn inner screw 1/4 turn clockwise to decrease
and counterclockwise to increase. 1/4 turn =
35°F. See graphic
Fig. 61.
6. Verify temperature setting at 350°F. Allow griddle
to cycle 3 complete times.
7. If not within 20°F then replace thermostat.
8. If temperature is within tolerance, adjustment is
complete.
9. Apply a small amount of Loctite 242 (non-
permanent type sealer) around the inner screw
head to prevent movement.
10. Install knob.
T+ER0OCOU3LETE6T
OSHUDWLRQ
The thermocouple supplies a DC millivolt signal (MV)
to the gas safety valve when heated by the pilot flame.
The gas safety valve will shut off gas flow to the pilot
and main burner in case of a pilot outage. When
energized by the thermocouple voltage, the gas safety
valve is held open to permit gas flow to the pilot and
provide gas for the burner when the oven thermostat
calls for heat. The pilot flame height is controlled by
an adjustable needle valve located under a small
cover screw on the gas safety valve.
3LORWCKHFNV
If experiencing pilot outages, perform the following:
Visually check pilot flame for the proper contact on
thermocouple and adjust as outlined under
PILOT
FLAME HEIGHT. If adjustment does not result in a
pilot flame of proper height, then gas might not be
flowing properly to the pilot.
Check for:
A plugged pilot orifice.
Kinked or plugged pilot gas tubing.
Low gas supply pressure.
TKHUPRFRXSOHCKHFNV
NOTE Tubing connection from the thermocouple tip
to gas safety valve is an electrical connection and
must be clean and dry. Do not use any sealing
compound on the threads of thermocouple nut.
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - SERVICE PROCEDURES AND
ADJUSTMENTS