PLANNING
The downdraft blower system is
designed to be used to exhaust
airborne contaminate when cooking
with a variety of gas or electric
cooktops. It can be mounted in an
island, peninsula, or conventional
wall location.
This unit can be easily installed
following these basic steps:
Cut out the countertop opening.
Mount the unit in the cabinet.
Connect the ductwork and
electrical.
Install the cooktop.
IMPORTANT NOTE: The high level
of airflow of this appliance may affect
the gas flame on some types of gas
cooktops. This is normal and will
cause no harm, but can be corrected
by lowering the speed of the blower.
4
D OWNDRAFT P RE-INSTALLATION
MEASURING
Refer to the cooktop installation
instructions for dimensions of cook-
top, countertop cut-out, and cabinet
requirements. The DD30I and DD30R
will fit in most 30" wide cabinets and
the DD36I and DD36R will fit in most
36" wide cabinets. However, it is rec-
ommended that oversized cabinets
be used for easier installation.
Cooktop depth can vary greatly
from one to another. This may cause
the fit of these two appliances to be
rather tight.
Pay attention to the areas of
potential interference shown in the
illustration. A countertop with a
raised lip and/or a backsplash may
not allow enough flat countertop for
a proper installation. Note that 2-3/8"
of flat countertop is required behind
cooktop and that 1-3/4" is necessary
between the back edge of the cook-
top and the inside of cabinet back.
IMPORTANT NOTE: You must allow
a minimum of 25" of flat counter top
space to accommodate any down-
draft system with an approved Wolf
cooktop.
Areas of potential interference
A
countertop
cooktop
B
downdraft
2
3
/8"
1
3
/4"
front to back
inside cabinet depth
Vista de página 3