Installation Information
2-3
DDuuaall FFuueell RRaannggee
Gas Requirements
Wolf Dual Fuel Ranges are manufactured to work with natural gas or LP gas (Liquid Propane gas). The model /
serial rating plate, located on the bottom of the control panel assembly just above the oven door on the far right, has
information on the type of gas that should be used. If this information does not agree with the type of gas available,
check with the local gas supplier.
Natural Gas Manifold Pressure
Standard natural gas orifices on the appliance are set for 5” WC (Water Column Pressure).
Liquid Propane Manifold Pressure
The standard propane gas orifices on the appliance are set for 10” WC (Water Column Pressure).
Gas Supply Line Size
3/4 inch rigid pipe to the range location
For LP gas, piping or tubing size can be 1/2"
minimum.
NOTE: A smaller size pipe on long runs may result in insufficient gas supply.
A CSA design-certified, 3-foot long, 1/2" or 3/4" ID,
flexible metal appliance connector is recommended
for connecting this range to the gas supply line.
Gas Supply Pressure
Maximum line pressure for natural gas and LP is 14” WC; 1/2 psi (3.5 kPa).
Minimum line pressure for natural gas is 7” WC.
Minimum line pressure for LP gas is 11” WC.
Gas Pressure Regulator
To control and maintain a uniform gas pressure in the
gas manifold, Wolf gas appliances must be connected
to the gas supply line through a pressure regulator.
The burner orifices are sized for the pressure delivered
by the regulator. Never attempt to operate a Wolf gas
appliance without the use of the proper pressure
regulator.
The maximum gas supply pressure to the regulator
should never exceed 14” WC (Water Column
Pressure); 1/2 psi (3.5kPa)
Do not kink or damage the connector when moving
the range