Figure 4-13. Components that Lift Off
Figure 4-14. Electrode and Infrared Burner Removal
Infrared Charbroiler Components
Cover, Grate, Char Pan, Radiant, Electrode, Infrared
Burner and IR Orifice
• Lift the Charbroiler cover from the unit.
• Lift the Charbroiler grate from the char pan.
• Lift the Charbroiler radiant from the char pan.
• Lift the Charbroiler frame from the top of the unit.
(See Figure 4-13)
Electrode Removal
The infrared Charbroiler electrode is attached to a
bracket with a screw and then mounted 1/8” above the
surface of the burner tile. The electrode wire is then
inserted into a wire sleeve and routed to the spark mod-
ule which is located underneath the deflector shield.
In order to remove the Charbroiler electrode, disconnect
the electrode wire from the spark module. Extract the
mounting screw from the electrode bracket and pull the
electrode with wire lead up through oblong hole in the
back wall. (See Figure 4-14)
Infrared Burner Removal
After removing the components listed above, extract the
screws securing the IR weld assembly. Then, extract
the screw from the rear of the IR burner box. Lift the
burner box out by first sliding the IR weld assembly
towards the rear. Next, lift the IR weld assembly up
and rest it on the ECH shield. Disconnect the gas line
from the brass orifice elbow. Now, lift the IR burner out
of the IR weld assembly. (See Figure 4-14)
IR Orifice Removal
The orifice is located in the brass orifice elbow, which is
threaded into the orifice holder at the front of the IR
burner. The IR weld assembly must be raised up and
placed on the ECH shield for access.
To remove the orifice, first disconnect the gas line from
the brass orifice elbow. Then, unscrew the elbow from
the orifice holder and extract the orifice from the elbow
with wrenches. (See Figure 4-15 and 4-16)
Figure 4-16. IR Charbroiler Orifice Removal
IR Charbroiler Orifice
Orifice Elbow
Figure 4-15. Flexible Gas Tube Removal
Comentários a estes Manuais