List of parameters, standard setting / System
Parameter list
Standard setting
This is found at control level 2 → Standard settings → Mixer 1
Check the BM installation and operating instructions for a description
of the parameters Standard temperature, Reduced temperature,
Gradient, Room inuence, WI / SU changeover and ECO-RED.
Parameters Setting range Factory setting
Individual
setting
TEMP DAY
5 °C - 30 °C 20°C
RED TEMP
5 °C - 30 °C 16 °C
GRADIENT
0 - 3 0.8
ROOM INFL
OFF - ON OFF
W/S SWITCh
0 °C - 40 °C 20 °C
ECO-RED
-10 °C - 40 °C 10 °C
Check the description of the parameters Room inuence, Frost
protection limit, Pump stop with room controller, Setback stop and
Maximum DHW temperature in the BM installation and operating
instructions.
A10: Parallel pump operation for KM or MM
Parameter a 10 = 0: Priority mode for cylinder heating or external
heat demand ahead of a heat demand for the
mixer circuit output.
Parameter a 10 = 1: Parallel mode for cylinder heating or external
heat demand with a heat demand for the
mixer circuit output.
Note: In parallel mode, the highest possible ow
temperature is applied.
Parameter list
Contractor system
The system parameters
A09
,
a10
,
a12
and
a14
can only be adjusted at
the programming module with address 0. All other system parameters
are adjusted at the associated programming modules.
This is found at control level 2 → Contractor → System
Parameters Setting range Factory setting
Individual
setting
A00
Room inuence 1 - 20 4
A09
Frost protection limit -20 - 10 °C 2
a10
Parallel pump operation
0 - 1 0
a11
Room temperature-
dependent summer/
winter changeover
ON - OFF ON
a12
Setback stop OFF, -39 °C -16
a14
Maximum DHW
temperature
60 - 80 °C 65