KM 01 Conguration The corresponding conguration may, subject to the application
of the KM, have to be selected. Up to 13 congurations can be
selected. corresponding wiring diagrams, see under "Electric
connection". Adjust the conguration during commissioning.
Conguration 01: Mixer circuit and cylinder circuit
Conguration 02: Mixer circuit and convector heater circuit
Conguration 03: Mixer circuit and heating circuit
Conguration 04: Cylinder circuit and third party boiler control
Conguration 05: Mixer circuit and return temperature raising for
heating backup
Conguration 06: Heating circuit and return temperature raising
for soft starting
Conguration 07: Mixer circuit with indirect return temperature
raising for soft starting
Conguration 08: Mixer circuit (factory setting)
Conguration 09: Heating circuit
Conguration 10: Cylinder circuit
Conguration 11: Convector heater circuit
Conguration 12: 0 – 10 V input for telecontrol system
Conguration 13: Return temperature raising, wood burning
boiler
Note: Only contractors should adjust the KM parameters.
Only operate boilers of the same type in a single cascade, i.e.
either modulating, single stage or two-stage boilers. Adjust the
conguration during commissioning.
km 02 = 1 ⇒ single stage boiler
km 02 = 2 ⇒ two-stage boiler
km 02 = 3 ⇒ modulating boiler (factory setting)
KM 02 Mode
The "Maximum header temperature" parameter limits the set
header temperature upwards.
KM 03 Maximum
header temperature
With the r.h. rotary selector, choose the cascade parameter to
be modied (KM..) from the contractor menu level (after entering
the correct code).
The cascade parameter to be modied (KM..) is changed by
pressing (display indicator ashes) and then turning the r.h. rotary
selector. After setting the cascade parameter to be modied (KM..),
pressing the r.h. rotary selector again conrms the setting.
Pressing the Info pushbutton returns the standard display.
Parameters / Function description